Can pipette design affect NGS success rates ?


DNA Yield: Smooth, defect-free bores minimize cell lysis during aspiration, preserving genomic DNA integrity. Sample Purity: Flared tips help isolate clean TE clusters without inner cell mass contamination. Consistency: Tight ID tolerances ensure reproducible cell counts—critical for accurate downstream amplification.


These micropipettes are supplied in boxes containing 10 individually packed and sterile units. This packaging format facilitates convenient handling and storage in the laboratory.


Minimal Pressure: Never exceed 150 hPa; steady, gentle suction preserves blastocoel integrity. Rapid Release: Once cells are aspirated, withdraw immediately to allow re-expansion. Timed Sampling: Limit total biopsy time to under 2 minutes per embryo.


Pre-Drill Opening: Create a small zona opening via laser or acid Tyrode to relieve elastic tension. Quick Entry: Insert pipette swiftly through the pre-drilled hole, then pause before applying suction. Supportive Holding: Use the holding pipette to counter-balance forces, keeping the blastocyst stable.


ICSI Pipettes: Inner diameter ~5–8 µm, Taper length 600 micrometers , sharp bevel for membrane penetration Biopsy Pipettes: Wider bore (15–35 µm ID) to aspirate multiple cells Longer taper (~900 µm) for added flexibility when sampling trophectoderm


Low Suction: Use the minimum negative pressure needed—typically 100–150 hPa—for smooth aspiration. Smooth Bevel: Fire-polish tips to eliminate micro-ridges that can tear cell membranes. Rapid Sampling: Complete each aspiration in <5 seconds to reduce exposure time and mechanical stress.


Focused Laser Cuts: If using laser, apply minimal pulses to detach only the targeted TE region. Controlled Aspiration: Gently expand the pipette mouth against the TE without “plucking” clusters. Pre-Equilibration: Allow blastocysts to acclimate in the biopsy drop for 1–2 minutes to reduce dynamic movements.


Common Causes : Variability in pipette tip size or shape Embryo positioning inconsistencies Inadequate zona opening techniques or tools Resolution Path : Use biopsy micropipettes from a reliable, precision-controlled manufacturer Standardize embryo orientation and zona opening method (e.g., laser or acid Tyrode) Ensure all embryologists follow a unified protocol for blastomere/TE extraction Document every biopsy step for pattern recognition and optimization


Cell Count Check: View the pipette tip under high magnification to confirm the intended number of cells. Blastocyst Assessment: Ensure post-biopsy the blastocyst re-expands and shows no large tears in the TE. Sample Transfer: Deposit cells into lysis buffer or PCR tube and visually confirm all cells left the pipette.


Shallow Approach: 20–30° relative to the dish reduces downward force on the blastocyst. Align with TE Layer: Match the pipette axis to the plane of the trophectoderm for an even, controlled cut or aspiration.


Blastomere Biopsy Micropipettes are specialized tools designed by Monash Biotech for performing blastomere biopsy in assisted reproductive technology (ART) procedures. These micropipettes are used for precision cell sampling during embryo biopsy.


Monash Biotech offers three categories of Blastomere Biopsy Micropipettes, each with various angles and designs: Straight, flat & 15° to 45° angled micropipettes (Catalogue No. MBB-F-S) Flat & 15° to 45° angled micropipettes (Catalogue No. MBB-F-M) Bevelled 15° to 45° angled micropipettes (Catalogue No. MBB-B) Each category has specific models with different angles and identical inner diameters (I.D.) of 30μm or 35μm.


Our Blastomere Biopsy Micropipettes offer precision and performance, available in two carefully selected inner diameters: 30µm and 35µm. These sizes are optimized for delicate blastomere biopsy procedures.


Monash Biotech's Trophectoderm Biopsy (Bevelled) Micropipettes are available in three inner diameter sizes: 15µm, 20µm and 25µm.


Monash Biotech's Trophectoderm Biopsy (Flat ) Micropipettes are available in three inner diameter sizes: 15µm, 20µm and 25µm.


Mechanical Trauma: Excessive injection pressure or pipette vibration Oocyte Quality: Intrinsic cytoplasmic defects or aged oocytes Media Osmolarity Shifts: Rapid changes in buffer composition Reactive Oxygen Species: Prolonged handling outside optimal conditions


Variable Suction: Fluctuating pressure leads to inconsistent cell uptake. Tip Diameter Mismatch: A pipette bore that’s too wide or narrow can grab too many or too few cells. Blastocyst Orientation: Off-axis holding makes some TE strands more accessible than others.


The taper length of our [Blastomere Biopsy Micropipettes](https://www.monashbiotech.com/blastomere-biopsy-micropipette/ "Blastomere Biopsy Micropipettes") is 900 micrometers.


The taper length of our Trophectoderm Biopsy (Bevelled) Micropipettes is 900 micrometers.


The taper length of our Trophectoderm Biopsy (Flat ) Micropipettes is 900 micrometers.


The taper length of the micropipettes is 900μm, contributing to precise and controlled cell sampling during blastomere biopsy.


Inner Diameter: TE pipettes are wider (~15–20 µm ID) to aspirate multiple trophectoderm cells at once, whereas blastomere pipettes are narrower (~10 µm ID) for single‐cell removal. Taper Length: TE pipettes have a longer taper (150–200 µm) to reach the TE layer without disturbing the inner cell mass; blastomere pipettes use a shorter taper (100–120 µm) for precise entry into individual blastomeres. Tip Geometry: TE tips are often slightly flared or fire-polished to scoop clusters, while blastomere tips have a sharper bevel for clean single-cell aspiration.


Experience precision and control with our Bevelled Blastomere Biopsy Micropipettes, available in a wide range of angles: from 15° to 45°, as well as 0° (straight). This versatility allows for optimal manipulation during biopsy procedures.


Our flat Blastomere Biopsy Micropipettes are available in angles ranging from 15 to 45 degrees. This range allows for precise and controlled manipulation of blastomeres during biopsy procedures.


Our Trophectoderm Biopsy (Bevelled) Micropipettes are available in angles ranging from 15° to 35°, as well as 0° (straight) degrees.


Our Trophectoderm Biopsy (Flat ) Micropipettes are available in angles ranging from 15° to 35°, as well as 0° (straight) degrees


Cell Clumps: Scooping multiple cells or debris can block the lumen. Viscous Media: High protein concentration in the biopsy drop can coagulate at the tip. Tip Damage: Micro-fractures from previous use snag cells.

FAQ Categories

Click on Your Topic to get answers

Explore More
Intrauterine Insemination
In Vitro Fertilization
Intracytoplasmic Sperm Injection
Injection Micropipettes
Trophectoderm Biopsy (Bevelled) Micropipettes
Trophectoderm Biopsy (Flat) Micropipettes
Zygote Intrafallopian Transfer
History
Gamete Intrafallopian Transfer
Frozen Embryo Transfer
Polar Body Biopsy Micropipettes
Holding Micropipette
Blastomere Biopsy Micropipettes

Got more questions?

Visit our full FAQ Page for in-depth answers or reach out to our Customer Support team.

Monash Biotech Pvt. Ltd.
Change Language
Monash Biotech Pvt. Ltd.

Home

Quality Pledge

About Us

Events Gallery

Blog

News & Updates

Please note that the 3D models displayed on this website are for illustrative purposes only. Actual product dimensions, colors, and finishes may vary.

© 2026 Monash Biotech Pvt. Ltd.. All Rights Reserved.

Designed & Developed by Goafreet Company