Monash Biotech Pvt. Ltd.
HomeAbout UsQuality PledgeResourcesSupport

FAQs on ICSI & Injection Micropipettes FAQs

ICSI & Injection Micropipettes FAQs

ICSI & Injection Micropipettes FAQs

Are there options for Monash Biotech Injection Micropipettes without a spike?


Yes, Monash Biotech offers micropipettes without a spike in 30° and 35° angled configurations with a bevel length of 11 μm and an inner diameter (I.D.) of 05 μm.


Yes—if the tip penetrates too deeply or contacts the spindle region directly. Prevention: Limit penetration depth to just past the zona and use spindle‐safe imaging (polarized light) when available.


Whether you prefer spiked or non-spiked tips, our Injection Micropipettes have you covered.


Our Injection Micropipettes offer versatility with two bevel length options: 11µm and 10µm. Choose the best option for your specific needs and preferences.


To get a personalized quote for ICSI injections, please contact our sales team directly. We will be happy to provide you with a detailed estimate based on your specific needs and requirements.


Stable Suction: Apply just enough negative pressure to grip the zona—avoid over-suction that deforms the oocyte. Symmetric Hold: Center the pipette on the oocyte’s widest plane, not off to one side. Oil Overlay: A thin oil layer damps fluid currents that can spin the oocyte when pipettes move.


Denudation: Remove cumulus–corona cells gently to visualize the oocyte. Polar Body Check: Confirm presence of the first polar body (MII stage). Spindle Imaging (optional): Use polarized-light microscopy to verify spindle integrity in high-value cases.


Critical Window: Oocytes are highly temperature-sensitive at 36.8–37.2 °C. Effects of Drift: Even a ±0.5 °C deviation can alter membrane fluidity and spindle stability, reducing fertilization success. Mitigation: Use a heated stage or enclosed incubation chamber to maintain constant temperature throughout the procedure.


Too Fast: High shear stress causes membrane tearing and spindle disruption. Too Slow: Prolonged contact increases oocyte exposure outside the incubator, elevating ROS risk. Ideal: A consistent moderate speed—penetrate the zona in ~1 s, then advance into the cytoplasm in 0.5–1


Thicker Zona (e.g., post-vitrification or in older oocytes) requires higher injection pressure or a slightly wider tip. Hardening (spontaneous or induced) can be mitigated by pre-treatment with calcium-free medium or brief acid-Tyrode exposure.


Thick or Hardened Zona: Increase bevel length slightly (5–10 µm) and raise injection pressure by 1–2 hPa. Pre-treatment: Brief acid-Tyrode or calcium-free incubation can soften the zona, reducing required force. Monitoring: Watch for “give” as the tip traverses the zona—avoid over-penetration beyond that point.


Cytoplasmic Appearance: Even granularity, absence of large vacuoles Zona Quality: Uniform thickness, no debris or dark cortical granules Polar Body Integrity: Single, clear first polar body without fragmentation


Cytoplasmic Darkening: Rapid darkening or granulation within 30 minutes Membrane Blebbing: Small blebs or protrusions on the oolemma Pronuclear Failure: Absence of two pronuclei at the 18–20 hour check


Signs: Excessive cytoplasmic leakage, large, persistent media droplets at the tip, or oocyte collapse. Prevention: Calibrate injection pressure and duration (e.g., 1–2 s pulses). Use the minimum volume needed to release the sperm. Monitor each injection under real‐time imaging.


Gradual Pressure Ramp: Program microinjector to ramp up suction/injection over 1–2 seconds Pre‐Drill: Create a small opening with a laser or acidic Tyrode before pipette entry Dampened Tip: Fire‐polish to produce a slightly rounded bevel that cushions entry


Generally no—post-injection aspiration risks: Disrupting the spindle apparatus. Introducing additional mechanical stress. Only consider a brief, gentle aspiration if confirming penetration depth or retrieving a biopsy sample.


Visible Fissures: Hairline cracks radiating from the pipette entry site Zona Chips: Glass shards or irregular zona fragments floating in the drop Increased Resistance: Sudden release of pressure when advancing through the zona


Successful: A brief “give” or release in pipette resistance. Slight cytoplasmic swelling around the pipette tip. Failed: Persistent high resistance or sudden loss of resistance without swelling. Cytoplasmic leakage or oolemma collapse around the tip.


Monash Biotech's Injection Micropipettes are available in three inner diameter sizes: 5µm, 7µm and 8µm.


Successful: A momentary drop in resistance (“pop”) as the membrane yields. Slight cytoplasmic swelling around the tip. Failed: Persistent high resistance with no give. Sudden loss of resistance without swelling (membrane bounce or “rebound”).


Two Pronuclei (2PN): Clear, centrally located pronuclei at ~16–20 h post‐inject. Second Polar Body Extrusion: Confirms completion of meiosis II. Pronuclear Alignment: Even separation from oolemma and opposite each other.


Oocyte Activation Failure: Insufficient calcium oscillations post‐injection. Sperm‐Related Issues: DNA fragmentation or chromatin decondensation defects. Spindle/Chromosome Damage: Mechanical trauma during penetration. Cytoplasmic Deficiencies: Poor ooplasmic maturation or metabolic insufficiency.


Common Causes : Sudden pressure changes during sperm injection Excessive force while penetrating the zona pellucida Manufacturing defects or micro-fractures from handling Avoidance Tips : Use micro-pipettes designed specifically for ICSI with reinforced tapering Control injection pressure using microinjector settings carefully Minimize contact between the micro-pipettes and the ICSI dish base Handle micro-pipettes with delicate forceps—never bare hands


Over‐Suction: Excessive negative pressure draws oolemma too tightly. Zona Breach: Damage allowing oil or medium to infiltrate. Osmotic Shifts: Rapid changes in surrounding media tonicity.


The micropipettes with a spike are available in 30° and 35° angled configurations with a bevel length of 11 μm and an inner diameter (I.D.) of 05 μm


Inner Diameter: ~5 µm at the tip to snugly hold a single sperm head. Outer Diameter: ~7–8 µm to penetrate the zona with minimal force. Taper Length: 90–120 µm for optimal rigidity and visibility under the microscope.


Inner Diameter: A 5 µm ID closely fits the sperm head, reducing cytoplasmic leakage and drag. Bevel Length: Short bevels focus force; long bevels (>15 µm) can slide through the zona without clean cuts. Wall Thickness: Thicker walls resist bending but may reduce visibility; aim for ~1 µm wall thickness at the tip.


After retrieval, oocytes are typically incubated for 2–4 hours to allow cytoplasmic maturation before ICSI. Performing ICSI within 3–5 hours post-pickup balances maximum fertilization potential with minimal oocyte aging.


Gentle Suction Modulation: Slightly reduce then increase holding pressure in sequence Oil-Overlay Method: Use fluid currents under oil to nudge the oocyte into position Microneedle Assistance: Lightly touch with a separate blunt pipette (not the injection pipette)


The taper length of our Injection Micropipettes is 600 micrometers.


Vibration-Damped Stage: Use anti-vibration tables or dampening pads under the microscope. Ergonomic Setup: Position joysticks, monitor, and pipettes to avoid operator fatigue and tremor. Batch Handling: Process small groups (5–10 oocytes) per session to limit total exposure time and keep procedures swift.


Extend Incubation: Give extra 30–60 minutes to allow cytoplasmic clearing Media Change: Transfer to fresh, low‐density medium to remove debris Evaluate Viability: Consider excluding severely granular oocytes that may have impaired spindle function


Bevel Sharpness: Maintain a 10–15° bevel for a defined cutting edge. Pre-drills or Piezo: In cases of tough membranes, use a brief laser pulse or piezo pulse to weaken the oolemma first. Depth Control: Retract the tip 1–2 µm after crossing the zona to position just outside the oolemma, then advance into the cytoplasm.


Increased Oocyte Aging: Extended exposure to outside-incubator conditions elevates reactive oxygen species and spindle disorganization. Recommended Workflow: Complete each ICSI batch within 15–20 minutes to preserve oocyte competence.


Too Shallow: Sperm may lodge in the zona or perivitelline space, failing to trigger activation. Too Deep: Risks spindle contact or cytoplasmic leakage, compromising embryo development. Optimal: Penetrate just past the oolemma—typically 2–3 µm into the ooplasm.


Stubborn Zona: Thick or hardened zona pellucida (e.g., post‐vitrification). Fragile Oocytes: Poor membrane elasticity in older or dysmorphic oocytes. Recurrent Injection Failures: Standard ICSI repeatedly fails activation.


High Fragmentation Load: Early cytoplasmic damage leads to cell death. Genetic Abnormalities: Chromosomal mismatches trigger lysis. Culture Conditions: Suboptimal media or temperature fluctuations causing degeneration.


Mechanical Trauma: Excessive shear disrupting cytoskeletal integrity. Activation Irregularities: Aberrant calcium signaling leads to asynchronous divisions. Intrinsic Defects: Ooplasmic or mitochondrial dysfunction affecting cell cycle dynamics.


Membrane Breach: Minor rips in the oolemma causing cytoplasmic leakage Osmotic Imbalance: Exposure to hypotonic or hypertonic medium during transfer Temperature Shock: Rapid cooling or warming during movement between drops


Cytoplasmic Injury: Localized trauma from tip movement. ER/Mitochondrial Clumping: Age or cryodamage can manifest as vacuoles. Metabolic Stress: Oxidative damage during handling.

FAQ Categories

Click on Your Topic to get answers

Explore More
Intrauterine Insemination
In Vitro Fertilization
Intracytoplasmic Sperm Injection
Injection Micropipettes
Trophectoderm Biopsy (Bevelled) Micropipettes
Trophectoderm Biopsy (Flat) Micropipettes
Zygote Intrafallopian Transfer
History
Gamete Intrafallopian Transfer
Frozen Embryo Transfer
Polar Body Biopsy Micropipettes
Holding Micropipette
Blastomere Biopsy Micropipettes

Got more questions?

Visit our full FAQ Page for in-depth answers or reach out to our Customer Support team.

Monash Biotech Pvt. Ltd.
Change Language
Monash Biotech Pvt. Ltd.

Home

Quality Pledge

About Us

Events Gallery

Blog

News & Updates

Please note that the 3D models displayed on this website are for illustrative purposes only. Actual product dimensions, colors, and finishes may vary.

© 2026 Monash Biotech Pvt. Ltd.. All Rights Reserved.

Designed & Developed by Goafreet Company